Compact Touch 3 in 1

  • Superior B-Scan Visualization
  • Work Faster and Smarter
  • Precision In A-Scan and IIol Calculation
  • Easy Glaucoma Screening with the Pachymetry Option
  • Mobile Versatility

Technical Specifications

B Mode

  • Adjustable gain: 20 to 110 db
  • Time gain control (tgc): 0 to 30 db
  • Dynamic range adjustment: 25 to 90 db
  • Storage of still images and video sequences (up to 10 second duration) on hard disk image post- processing tools: calipers, areas, markers, comment

10mhz probe
  • Transducer frequency: 10 MHz
  • Angle of exploration: 50°
  • Depth of exploration: 20 to 60 mm (0.79" to 2.36")
  • Focus: 24 to 26 mm (0.94" to 1.02")
  • Axial resolution: 200 μm
  • Lateral resolution: 600 μm
  • Frame rate acquisition: up to 16 Hz

Biometry
  • Adjustable gain: 20 to 110 db
  • Time gain control (tgc): 0 to 30 db

11 mhz probe
  • Transducer frequency: 11 MHz
  • Tip diameter: 7 mm (0.28")
  • Electronic resolution: 0.03 mm (0.002")
  • Depth: 60 mm (2.36") on 1536 points
  • Contact and immersion techniques compatible
  • Aiming beam: led or laser pointer probeamtm*

Axial length measurements
  • Ultrasound propagation velocity adjustable per segment (anterior chamber , lens, vitreous) and iol and vitreous, material
  • Built-in-pattern recognition: phakic, aphakic, pmma, acrylic and silicone material for pseudo- phakic eye types
  • Automatic calculation of standard deviation and average total length (series of 10 measurements)
  • Acquisition modes: automatic, auto + save, manual
  • Automatic detection of scleral spike

IOL calculation
  • SRK-T, SRK-2, Holladay, Binkhorst-II, Hoffer-Q, Haigis
  • Post-op refractive calculation: pre-op and post-op refraction, pre-op and post-op keratometry
  • 6 different methods for keratometric correction and implant calculation: history derived, refraction derived, contact lens method, rosa regression, Shammas regression, double K/SRK-T (Dr. Aramberri’s formula)
  • 9 values bracketed for desired ametropia for each iol (iol increment steps: 0.25d or 0.50d)
  • Simultaneous display of 4 different iol calculations

Data management
  • Built-in physician and patient database
  • Exportation of still images and video sequences
  • Customizable digital and printed reports
  • EMR compatible
  • Compatible with PC and USB video printers

Pachymetry*
  • Transducer frequency: 20 MHz
  • Tip diameter: 1.2 mm (0.05")
  • Method: contact
  • Convergence: 0.5 mm (0.02") from the tip
  • Angle: 45°

Corneal thickness measurements
  • Measurement range: 200 to 999 microns
  • Number of measurements: 1 to 10
  • Precision: ± microns
  • Velocity: adjustable
  • Methods: central measurement or cartographic map
  • (Automatic, Continuous, Scanning)
  • Cartographic Map: user - 8l - 4l - 9c8l - 9c4l – 5c8l – 5c4l – 9c – 5c
  • Bias correction: up to 120%

IOP Correlation tables
  • Tables correlating intraocular eye pressure and corneal thickness: Ehlers + Doughty + Dresdner + unlimited user-defined tables

General information
  • Back-lit LCD color touch screen monitor
  • Electrical requirements
  • Power supply: 100-240 vac ± 10% single phase without earth
  • Frequency: 47-63 Hz
  • Power: 70 VA max

Features
  • Overall dimensions: 37.5 cm (w) x 10 cm (d) x 27 cm (h)
  • 14.76" (w) x 3.94" (d) x 10.63" (h)
  • Touch screen dimensions: 21 cm (w) x 16 cm (h); 8.27" (w) x 6.3" (h)
  • Weight: 4.2 kg (9.26 lb)
  • Ports: 2 USB, 1 Ethernet

Peripherals and accessories
  • Keyboard* with USB
  • Mouse with USB
  • External PC printer Windows 7 compatible *
  • Video printer with USB connection*
  • Footswitch
  • Carrying case
  • Connection to medical servers via EMR




COPYRIGHT © 2014 TECHNO VISION. DESIGNED & DEVOLOPED BY G5WEB SERVICES