Aviso, the Ultrasound Platform

  • Image Quality First
  • Powerful and User Friendly Interface
  • Dicom & Emr Compatible
  • Quantel Medical’s Proprietary Magnetic 50 MHZ With Linear Scanning Ultrasound Biomicroscope (Ubm) Probe Technology
  • Glaucoma Management
  • Cataract and Refractive Surgery
  • General Examination
  • Glaucoma Module: Qualify and Quantify
  • High-Frequency 20 MHZ for Posterior Segment Imaging
  • Biometry Module Standardized Echography

Technical Specifications

B Scan Modes


Grey Levels: 256

  • Adjustable Gain: 20to 110 Db
  • Time Gain Control (Tgc): 0 To 30 Db
  • Manual And Synchronized Dynamic Adjustment From 25 To 90 Db
  • Unlimited Storage Capacity For Still Images And Video Sequences (Up To 40 Second Duration)
  • Image Post-Processing Tools: Algorithmic & Color Image Filters, Calipers, Areas, Angles, Markers, Comments Glaucoma Quantifying Semi-Automated Tools With Aod 500 & 750, It 750 & 2000, Tia, Ara 500 & 750, Tisa 500 & 750, Lv


Posterior Pole Examination


Magnetic 10 MHZ Probe


  • Transducer Frequency: 10 MHZ
  • Angle Of Exploration: 50°
  • Depth Of Exploration: 20 To 60 Mm (0.79” To 2.37”)
  • Focus: 21 To 25 Mm (0.83” To 0.98”)
  • Axial Resolution: 150 ΜM
  • Lateral Resolution: 300 ΜM
  • Frame Rate Acquisition: Up To 16 Hz


Magnetic 20 MHZ Probe for Posterior Pole*


  • Transducer Frequency: 20 MHZ
  • Angle Of Exploration: 50°
  • Focus: 24 To 26 Mm (0.94” To 1.02”)
  • Axial Resolution: 100 ΜM
  • Lateral Resolution: 250 ΜM
  • Frame Rate Acquisition: Up To 16 Hz


Ubm & Anterior Segment Examination*


Magnetic 50 MHZ Ubm Probe with Linear Scanning


  • Transducer Frequency: 50 MHZ
  • Linear Transducer Movement: Exploration Width 16mm (0.63”)
  • Focus: 9 To 11 Mm (0.35” To 0.43”)
  • Axial Resolution: 35 ΜM
  • Lateral Resolution: 60 ΜM


Linear 25 MHZ Ubm Probe


  • Transducer Frequency: 25 MHZ
  • Linear Transducer Movement: Exploration Width 16mm (0.63”)
  • Focus: 11to 13 Mm (0.43” To 0.51”)
  • Axial Resolution: 70 ΜM
  • Lateral Resolution: 120 ΜM


Data Management


  • Built-In Physician And Patient Database
  • Exportation Of Still Images And Video Sequences
  • Customizable Digital And Printed Reports
  • Dicom* And/Or Emr Compatible
  • Compatible With Pc, Usb Video And Dicom Printers


Biometry


  • Adjustable Gain: 20 To 110 Db
  • Time Gain Control (Tgc): 0 To 30 Db


11 MHZ Probe


  • Transducer Frequency: 11 MHZ
  • Tip Diameter: 6 Mm (0.23”)
  • Electronic Resolution: 0.04 Mm (0.002”)
  • Depth: 40/80 Mm On 2048 Points
  • Contact And Immersion Techniques Compatible
  • Aiming Beam: Led Or Laser Pointer*


Axial Length Measurements


  • Ultrasound Propagation Velocity Adjustable Per Segment (Anterior Chamber, Lens, Vitreous) And Iol And Vitreous Material
  • Built-In Pattern Recognition: Phakic, Aphakic, Pmma, Acrylic And Silicone Material For Pseudo-Phakic Eye Types
  • Automatic Calculation Of Standard Deviation And Average Total Length (Series Of 10 Measurements)
  • Acquisition Modes: Automatic, Auto + Save, Manual
  • Automatic Detection Of Scleral Spike


Iol Calculation


  • Srk-T, Srk 2, Holladay, Binkhorst-Ii, Hoffer-Q, Haigis
  • Post-Op Refractive Calculation: -Pre-Op And Post-Up Refraction, Pre-Op And Post-Op Keratometry
  • 6 Different Methods For Keratometric Correction And Implant Calculation: History Derived, Refraction Derived, Contact Lens Method, Rosa Regression, Shammas Regression, Double K/Srk-T (Dr. Aramberri’s Formula)
  • 7 Values Bracketed for Desired Ametropia for Each Iol (Iol Increment Steps: 0.25d Or 0.50d)
  • Simultaneous Display Of 4 Different Iol Calculations


General Information


  • Connection: Connectable To Pc Systems Via Usb-2 Port Operating Under Windows 8 / Windows 7
  • Dedicated Software for Communication Driving Between The Acquisition Module And Computer
  • Images Displayed On The Computer Monitor

COPYRIGHT © 2014 TECHNO VISION. DESIGNED & DEVOLOPED BY G5WEB SERVICES